Global Utilities , is one of the Canada’s all engineering commodities, parts, instruments, equipments and plants. And we are proud to offer One stop Shopping for electrical, mechanical, construction and other integrated supply for processing / manufacturing plants, utilities and construction companies.
OPGW is one of the special optical fiber cables electrical power lines which are installed at the towers or poles of the aerial power transmission lines. Global Utilities can supply following parts according to IEEE Standard 1138-2002: • IEEE standard Construction of Composite Fiber Optic overhead Ground Wire (OPGW) for use on Electric utility power lines. And following parts according to IEEE Standard 1222-2004: • IEEE Standard for all di-electric self-supporting Fiber optic cable.
OPGW offered by globalutiliites has been tested for all major type tests from kinetrics Lab in Ontario, Canada.
Test Name | Specification |
Aeolian Vibration Test | IEEE Standard 1138, Paragraph 4.1.1.4 |
Bend Test | IEC 60794-1 E11, Procedure 2 |
Cable Cut-off Wavelength | IEEE Standard 1138, Paragraph 4.1.1.12 |
Creep Test | IEEE Standard 1138, Paragraph 4.1.1.8 |
Crush Test | IEEE Standard 1138, Paragraph 4.1.1.7 |
Galloping Test | IEEE Standard 1138, Paragraph 4.1.1.5 |
Impact Test | IEEE Standard 1138, Paragraph 4.1.1.7 |
Lightning Test | IEEE Standard 4 |
Salt Spray Corrosion Test | EIA/TIA 455-24A |
Seepage of Flooding Compound | IEEE Standard 1138, Paragraph 4.1.1.2 |
Sheave Test | IEEE Standard 1138, Paragraph 4.1.1.6 |
Short Circuit Test | IEEE Standard 1138, Paragraph 4.1.1.3 |
Strain Margin/Tensile Performance | IEEE Standard 1138, Paragraph 4.1.1.10 |
Stress-Strain/Fibre-Strain Test | IEEE Standard 1138, Paragraph 4.1.1.9/4.1.1.11 |
Temperature Cycle Test | IEEE Standard 1138, Paragraph 4.1.1.13 |
Water Ingress Test | IEEE Standard 1138, Paragraph 4.1.1.1 |
• Fiber Court and Type • Structure of Cable • Overall Diameter (mm) • Calculated Sectional Area (mm²) • Calculated Mass(kg/km) • RTS-rated Tensile Strength(kN) • Elastic Modulus(N/mm²) • Linear Expansion Coefficient(1/°C) • DC Resistance( Ω/km) • Short Current Capacity(kA²s) • MAT-Max Allowable Tensile Strength(kN) • Storage and Operating Temperature (°C) • Strain Margin(%) • Outer Layer Standing Direction Put your specifications and get a quote now.
View Specifications Download Complete Details Put your specifications and get a quote now.
Download Complete Details Put your specifications and get a quote now.
View Specifications Download Complete Details Put your specifications and get a quote now.